CAB A6 Manuel de l'opérateur Page 125

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 138
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 124
E-3cab Produkttechnik GmbH & Co KG
A3-2 / A3 / A4 / A6
18 9 10 8 11 6
6. Carefully unplug the printhead (1) from the connectors of the printhead
cables (9 and 10).
7. Connect the new printhead to the cables.
8. Place the printhead into the assembly and insert the holes (8) onto the
pins (11).
9. Tighten the locking screw (5) by hand. Check that the printhead is
completely secured in the printhead carriage.
10. Swing the lever (6) again into the position shown in figure E-2.
11. Tighten the locking screw (5) completely. Do not over-tighten the locking
screw (5).
Fig. E-3 Changing Printhead A3-2/A3/A4 (II)
Appendix E - Replacing Assembly Units